Gigahertz Optik logotipo

Contacto rápido

Gigahertz Optik GmbH (Sede central)
Teléfono: +49 (0)8193-93700-0
info@gigahertz-optik.de

Gigahertz-Optik, Inc. (Oficina de US)
Teléfono: +1-978-462-1818
info-us@gigahertz-optik.com

Lista de observación

You can add products to the watchlist and compare them with one another or send us an inquiry. There are watchlist symbols on product pages and product tables for this purpose.

Este producto ya no se fabrica. Es posible que queden existencias. Consulte las alternativas que figuran a continuación en "Productos similares" o póngase en contacto con nosotros directamente.

Productos alternativos para este producto descatalogado:

BTS2048-VL
Versatile superb Speed and high Quality LED Spectroradiometer
LDM-1901
Photobiological risk group classification (spectral or integral measurement)
X1-3
Optometer for the measurement of UV and Blue-light hazard of artificial radiation source.
X1-4
Broadband radiometer for radiation protection measurements of UV radiation devices

XD-45-HB

Detector for Blue-Light Hazard Measurements

  • Multi-cell detector with 45 mm diameter: Blue Light Hazard, Irradiance and Illuminance
  • Optional Adapter for effective radiance
  • For the use with X1-3 optometer
  • Compatible to standards IEC/EN 62471 as well as guidelines 2006/25/EC and IEC TR 62778
  • Including calibration certificate
XD-45-HB

The XD-45-HB-4 irradiance detector is specially designed for the evaluation of Blue light exposure hazard values for artificial light sources. The four sensor design of this unique device covers the requirements for eye risk assessment. It supports a number of standards and regulations:

  • IEC 62471:2006 and EN 62471:2008
  • 2006/25/EC
  • IEC TR 62778:2014


Three Sensor B(λ) Design 

The Blue Light Hazard spectral responsivity for eye risk evaluation is formed by three filtered sensors for the BLUEUA300-400, BLUE400-600 and BLUERED600-700 spectral ranges. The IEC/EN 62471 conformal B(λ) detector is useful for evaluation of any type light source that contains UV-A and deep red light content. 

Additional Illuminance Sensor 

An extra V(λ) photometric sensor for illuminance measurement in lx is installed to establish the 500 lx reference distance protocol for illuminance and/or radiance qualification. All four filtered sensors are mounted behind a 20 mm diameter cosine diffuser. 

Traceable Calibration 

Calibration of the B(λ) (W/m²) and Ev (lx) detector responsivity is performed by the Gigahertz-Optik GmbH calibration laboratory for optical radiation measurements quantities. As with all light detectors supplied by Gigahertz-Optik calibration of absolute detector responsivity as well as detector individual measured relative spectral responsivity data is included. 

Steradian Tube for Radiance 

The optional XD-45-HB-SRT200 steradian tube is a unique tool for product qualification measurements of blue light hazard at the recommended distance of 200 mm. The tube attaches to the front of the XD-45-HB detector head and includes two exchangeable aperture plates to form a 100 mrad (20 mm diameter) and 11 mrad (2.2 mm diameter) field of view as stated in IEC 62471:2006 and EN 62471:2008 limit values. The tube is made out of light weight plastic with internal baffles and low reflection coating to reduce side wall stray light traversing down the barrel. The XD-45-HB-SRT200 steradian tube is an optionally available detector accessory component. No extra calibration is required. 

Recommended Optometers 

For applications involving steady state light the X13 optometer is recommended. For unstable or short event light the optometer P-9801 should be selected.
XD-45-HB B(λ) 3-sensor detector - typ. spectral responsivity

XD-45-HB B(λ) 3-sensor detector - typ. spectral responsivity

XD-45-HB V(λ) Detector - typ. spectral responsivity

XD-45-HB V(λ) Detector - typ. spectral responsivity

Productos similares

XD-45-HB
Photobiological risk group classification (spectral or integral measurement)
XD-45-HB
Optometer for the measurement of UV and Blue-light hazard of artificial radiation source.
XD-45-HB
Broadband radiometer for radiation protection measurements of UV radiation devices