Gigahertz Optik logotipo

Contacto rápido

Gigahertz Optik GmbH (Sede central)
Teléfono: +49 (0)8193-93700-0
info@gigahertz-optik.de

Gigahertz-Optik, Inc. (Oficina de US)
Teléfono: +1-978-462-1818
info-us@gigahertz-optik.com

Lista de observación

You can add products to the watchlist and compare them with one another or send us an inquiry. There are watchlist symbols on product pages and product tables for this purpose.

Este producto ya no se fabrica. Es posible que queden existencias. Consulte las alternativas que figuran a continuación en "Productos similares" o póngase en contacto con nosotros directamente.

Productos alternativos para este producto descatalogado:

ISD-5P-Si
Integrating sphere detector for Laser power in W

LP-9901

Detector head to measure Laser radiant power in W and Laser irradiance in W/m²

  • Low height detector with 7 mm diameter active area (suited for laser safety measurements)
  • 400 nm to 1100 nm
  • for the usage with optometers and signal amplifiers
  • including calibration certificate
LP-9901

Laser Radiation Detector

Laser radiation is measured in the same radiometric measurement units as polychromatic light sources. But Laser detectors are generally listed separately since they are designed specifically for laser measurement and calibrated accordingly. A typical Laser detector consists of a photodiode with or without attenuating filter calibrated at the Laser wavelength(s). 

Measurement of Laser Power in W 

To measure Laser power the detector area must be larger than the LASER spot size on the detector surface so that the total beam power is measured. Flat surface Laser detectors offer active areas of up to 1cm². Bare photodiodes can measure very low Laser power levels in the picowatt range but are limited to about one milliwatt before saturation of the photodiode. The upper range limit can be extended using neutral density filters. When using bare photodiodes or attenuating filters back reflected Laser radiation must be considered for both hazard and application implications.


Measurement of Laser Power Density in W/m² 

Measuring Laser power density is identical to the measurement of irradiance. Flat surface Laser detectors can be used to measure the Laser power density if the Laser radiation overfills the detectors active area.
For Laser hazard measurements a Laser power density detector with a 7mm diameter active area representing the maximum opening of human eyes pupil is recommended.


Flat Surface Laser Detector

The LP-9901 flat surface Laser detectors feature a 7mm Diameter active area. The neutral density filter extend the measurement range up to 50 mW in the spectral range from 400 nm to 1100 nm.


Traceable Laser Safety Detector Calibrations

Calibration of radiant power in W is performed at Gigahertz-Optik’s Calibration Laboratory for Optical Radiation Quantities.

Typical Spectral Responsivity

Typical Spectral Responsivity

Productos similares

LP-9901
Detector for fast, time-resolved (ns) radiant power measurement of pulsed laser diodes and LEDs
LP-9901
Optical Power Meter Detector for fast, time-resolved (ns) radiant power measurement of pulsed laser diodes and LEDs
LP-9901