Productos alternativos para este producto descatalogado:

ISS-50-LU-FE

Integrating Sphere Source with Spherical Illuminated Field for the Uniformity and White balance of Fisheye Cameras

  • Test device position in sphere center, ideal suited for fish-eye cameras
  • Halogen lamps with filter wheel selected correction filters
  • RGB monitor detector
  • Remote control electronics
ISS-50-LU-FE

Uniformity adjustment of fisheye cameras

Digital cameras with fisheye and super-wide angle lenses are characterized by viewing angles of up to >180°. Since these cameras map a hemispherical image in front of the objective lens on the image plane, reference light sources with a hemispherical illuminating field are required for uniformity matching. Please see our technical article "Integrating sphere source for homogeneity and white balance of fisheye cameras".


 

Integrating sphere source with spherical illuminated field

Integrating sphere based ,uniform light sources‘ offer luminous fields with highly uniform light distribution. In order to provide Fisheye cameras with a hemispherical illuminating field for uniformity matching, the camera must be placed in the center of the integrating sphere. This requirement significantly increases the design complexity of the integrating sphere ant its associated light sources and baffles.


 

White balance with different light spectra

Together with the uniformity adjustment, a white balance can be set for color cameras. In order to optimize the camera’s performance under different lighting conditions, the uniformity and white balance should be carried out at more than one color temperature.


 

Integrating sphere sources from a modular range

A special feature of the modular integrating sphere system of Gigahertz-Optik GmbH is the range of standardized assemblies. Integrating spheres of different diameters, mounting racks, port frames, port adapters, light sources, apertures, mounts for interchangeable filters and much more are produced as standard components. Configurations using these standard parts can be designed quickly in 3D CAD. As necessary, custom assemblies can also be manufactured. Please see our technical article "Modular Integrating Sphere Concept"


 

Control electronics and lamp power supplies

The electronic modules of the RM series of Gigahertz-Optik GmbH form a useful addition to the modular integrating sphere system. The 19" rack-mountable modules can be used to build high-quality electronic units for system control, power supply and monitoring. RS232, USB and Ethernet interfaces are available for remote control.


 

ISS-50-LU-FE integrating sphere source

Comprises:

  • Integrating sphere with 50 cm diameter
  • Test device positioning in sphere center via light-tight tube
  • Transparent dome with a diameter of 70 mm
  • 3x halogen light sources on 120 ° pitch for uniform light distribution
  • ODP97 coating of all relevant assemblies
  • 3x remote controlled filter wheels each with 3 filter holders for optical correction filters
  • Baffle to ensure homogeneous light propagation
  • Individually adjustable apertures for intensity adjustment of each lamp (color temperature-neutral)
  • Monitor detector for luminance and color temperature of the hemispherical light field
  • System controller for manual and remote control operation.

  

Calibration and adjustment

The supplied calibration comprises:

  • Traceable calibration of the spectral radiance for the spectral range 300 nm to 1100 nm
  • Calculation of the luminance and color temperature from the spectral measurement data
  • Matching each lamp to the specified color temperature
  • Matching the monitor detector to the output luminance and color temperature
  • Calibration certificate including calibration procedure, the calibration references used, the measured values and Calibration uncertainties.
  • Optional: Calibration of luminance distribution
Fig. 1: ISS-50-LH-FE integrating sphere source

Fig. 1: ISS-50-LH-FE integrating sphere source

Fig. 2: Open integrating sphere with transparent dome

Fig. 2: Open integrating sphere with transparent dome

Fig. 3: Electronic unit for system control, power supply and monitoring

Fig. 3: Electronic unit for system control, power supply and monitoring

Productos similares

ISS-50-LU-FE
Uniform Integrating Sphere Light Source in Accordance with EMVA 1288
ISS-50-LU-FE
Integrating Sphere Source with Variable and Stepwise Intensity Control
ISS-50-LU-FE
Versatile Integrating Sphere Uniform Light Sources for High Dynamic Range Test and Calibration of Imaging and non-Imaging Devices
ISS-50-LU-FE
LED based versatile Integrating Sphere Uniform Light Sources for High Dynamic Range Test and Calibration of Imaging and non-Imaging Devices with spectral reference sensor and intuitive S-ISS software