Gigahertz Optik logotipo

Contacto rápido

Gigahertz Optik GmbH (Sede central)
Teléfono: +49 (0)8193-93700-0
info@gigahertz-optik.de

Gigahertz-Optik, Inc. (Oficina de US)
Teléfono: +1-978-462-1818
info-us@gigahertz-optik.com

Lista de observación

You can add products to the watchlist and compare them with one another or send us an inquiry. There are watchlist symbols on product pages and product tables for this purpose.

Este producto ya no se fabrica. Es posible que queden existencias. Consulte las alternativas que figuran a continuación en "Productos similares" o póngase en contacto con nosotros directamente.

Productos alternativos para este producto descatalogado:

BN-Rxx-SQ
Calibration Standards for Diffuse Reflection

BN-Rxx-D2

Calibration Standards for Diffuse Reflection

  • Reflectance from 2 % to 98 % at 555 nm
  • ODM98 or ODMP disc with 50.8 mm diameter
  • Housing with screw cap
  • 8°/D calibration from 250 nm to 2450 nm with calibration certificate
BN-Rxx-D2

Reflection standards are used to calibrate and verify spectrophotometers, spectral colorimeters, and other spectroscopic instruments. For the 100% adjustment of the measuring devices, white standards with the highest possible reflectance are used. Linearity tests are performed with greyscale standards of different reflectances.


BN-Rxx-D2 reflection standards

are made of white ODM98 and grey to black pigmented ODMP. ODM98 offers the highest possible reflectance in the wavelength range 250 nm to 2500 nm and is therefore commonly used as a 100 % reference in spectrophotometers. As a translucent material, the material also offers near perfect Lambertian reflection. The reflective standards have a diameter of 50.8 mm / 2" and are supplied in a black housing.The protective lid closes simply with a quarter turn avoiding the need for fiddly fine threads.The BN-Rxx-D2 reflection standards are available with reflectivities of 98%, 70%, 50%, 20% and 2%.


Traceable calibrations

Each reflection standard is supplied with an individually prepared calibration certificate for the wavelength range from 250 nm to 2450 nm. The calibration is carried out by the Calibration Laboratory for Optical Radiation Measurements at Gigahertz-Optik GmbH. The calibration is traceable to the Physikalisch-Technische Bundesanstalt (PTB).


Working standards

Alternatively, the reflection standards are also offered without calibration for use as working standards . In this case, the user performs the calibration on his own using a calibrated reflection standard.

Typical Spectral Reflectance of BN Rxx Series

Typical Spectral Reflectance of BN Rxx Series