Gigahertz Optik logotipo

Contacto rápido

Gigahertz Optik GmbH (Sede central)
Teléfono: +49 (0)8193-93700-0
info@gigahertz-optik.de

Gigahertz-Optik, Inc. (Oficina de US)
Teléfono: +1-978-462-1818
info-us@gigahertz-optik.com

Lista de observación

You can add products to the watchlist and compare them with one another or send us an inquiry. There are watchlist symbols on product pages and product tables for this purpose.

Este producto ya no se fabrica. Es posible que queden existencias. Consulte las alternativas que figuran a continuación en "Productos similares" o póngase en contacto con nosotros directamente.

Productos alternativos para este producto descatalogado:

BN-LHSF-2P-20
Calibration standard lamp for 2π spectral flux, total flux and CCT
BN-1501
Calibration Standard Lamp for spectral irradiance in UV

BN-LDSF-2P

Calibration standard lamp for spectral radiant power in UV in 2Pi geometry

  • Deuterium lamp for 1.0HL port in 2Pi geometry
  • Calibration of spectral radiant power from 200 nm to 400 nm
  • Power supply optional
BN-LDSF-2P

Calibration standard lamp as reference standard for spectral radiant flux

One of the common measures of optical radiation is total radiant flux (or total radiant power). This measure measures the total flux of a light source in W. For the calibration of measurement devices (spectroradiometers) of spectral radiant flux in W/nm, calibrated light sources are required. These must ideally have within the spectral responsivity range of the instrument to be calibrated, a continuous spectral distribution and be traceable to a National Metrology Institute (NMI) calibration. In addition, the lamps used must meet high requirements with regard to their short-term and long-term stability. The most commonly used halogen lamps, however, provide too little signal in the UV range, which is why deuterium lamps are often used there. These provide a usable calibration range from 200 nm to 400 nm.


Reference standard BN-LDSF-2P

The reference standard BN-LDSF-2P is based on a 30 W deuterium lamp integrated in a housing with a diffuser to calibrate an integrating sphere in 2Pi geometry in spectral radiant power (for example for the precise measurement of UV LEDs). The electrical connection is made via laboratory sockets. The 1.0HL mechanical connection allows a precise and reproducible connection of the BN-LDSF-2P to an integrating sphere.

Each lamp is subjected to a recorded burn-in process before being released. Only lamps that meet the strict burn-in criteria will be released.


Traceable calibration

The calibration of the spectral radiant flux by the Calibration Laboratory for Optical Radiation Measurements of Gigahertz-Optik GmbH is traceable to common National Metrology Institutes (NMI) such as the Physikalisch Technische Bundesanstalt (PTB).


Special lamp power supply LPS-D-30

Deuterium lamps require a special power supply for operation. The LPS-D-30 is suitable for the BN-LDSF-2P.

Deuterium calibration standard for the UV range in 2Pi geometry

Deuterium calibration standard for the UV range in 2Pi geometry

BN-LDSF-2P on integrating sphere mounted (1.0HL port)

BN-LDSF-2P on integrating sphere mounted (1.0HL port)

Productos similares

BN-LDSF-2P
Calibration standard lamp for 2π spectral flux, total flux and CCT
BN-LDSF-2P
Calibration Standard Lamp for spectral irradiance in UV
BN-LDSF-2P
LED based calibration standard according CIE reference spectrum L41 (CIE 251) lamp for luminous flux or irradiance including electrical supply and temperature stabilization