Este producto ya no se fabrica. Es posible que queden existencias. Consulte las alternativas que figuran a continuación en "Productos similares" o póngase en contacto con nosotros directamente.
Productos alternativos para este producto descatalogado:
BN-0001
Calibration standard lamp for spectral irradiance. Features: 1000W tungsten halogen lamp. Burn-in certificate. Stable filament. Horizontal calibration from 250-2500nm with factory or DAkkS certificate.
Calibration standards
Calibration standards enable the calibration and correction of measurement instruments to absolute measurement quantities. Calibration standards provide a reference signal corresponding to the measurement quantity to be calibrated. The reference signal of the calibration standard is calibrated in the respective measurement quantity. The calibration of the measurement instrument is performed by comparing the measurement signal of the measurement device with the standard specifications in the calibration certificate. Deviations are compensated for by comparison the measurement instrument accordingly.
Spectral irradiance
The spectral irradiance [W/m²·nm-1] is important for qualification of the incident radiant flux of a reference plane. Spectralradiometers are the typical measurement devices for the spectral irradiance. Calibration of the spectralradiometer is done using a calibration standard lamp for the irradiance.
BN-0001 calibration standard lamp
Gigahertz-Optik GmbH offers the BN-0001 calibration standard lamp for applications where vertical alignment of the calibrating device is required. This has a 1000W DXW quartz halogen bulb for the usable spectral range between 250 and 2500nm. The lamp is firmly fixed into the socket. The electrical contact is installed through braze-welding. This sophisticated mounting and electrical connection ensures maximum position accuracy of the lamp and maintains a constant electrical resistance at the contacts. The standard lamp connection is done using robust ceramic terminal strips. Each standard lamp is burned-in before it is calibrated. The suitability of the lamp as a calibration standard is assessed based on its burn-in behavior.
BN-001Z-01 crosshair
The BN-0001Z-01 crosshair is fastened onto the socket of the standard lamp using dowel pins. It enables precise alignment of the measurement instrument during calibration of the standard lamp and the calibrating measurement devices to the same point of the lamp filament.
Traceable factory calibrations
The factory calibrations of the spectral irradiance from 250 to 1100nm are performed by Gigahertz-Optik’s calibration laboratory for optical radiation measurement quantities. The calibrations are traceable to calibration standards of Gigahertz-Optik’s calibration laboratory that is accredited by ISO/IEC 17025 (D-K-15047-01-00). Calibration and results of the calibration are confirmed by a calibration certificate conforming to the ISO 17025 specifications.
Typical emission spectrum
BN-0001 with BN-0001Z-01 crosshair