Spectral Radiance / Luminance Calibration Standards
Standard lamps calibrated in luminance and spectral radiance. Traceable calibrations in the wavelength range from 250 nm to 2500 nm.
Integrating sphere based standards (50mm to 500mm diameter) with tungsten halogen and LED sources (white, RGB-coloured and NIR).
Model | Image | Sphere Diameter | Light output port | Calibrated spectral range / nm | Light source | Output range | Remark | |
---|---|---|---|---|---|---|---|---|
ISS-5P | 50 mm |
20 mm |
(380 - 1100) nm | Integrated 10 W tungsten-halogen | ||||
ISS-5P-SR-FS | 50 mm | (380 - 1700) nm | LH-5-UV-Quartz halogen | e.g. for fluorescence spectrometer calibration | ||||
ISS-8P-HP | 80 mm |
19 mm |
(380 - 1100) nm | External up to 100W tungsten-halogen |
(120, 12 & 1.2) kcd/m² @ CCT 2960K (75, 75, 0.75) kcd/m² @ CCT 2856K |
|||
ISS-8P-VA | 80 mm |
19 mm |
(380 - 1100) nm | External up to 100W tungsten-halogen |
(0 - 95000) cd/m² @ CCT 2960K (0 - 63000) cd/m² @ CCT 2856K |
Continually variable intensity control. | ||
ISS-8P-VAHP | 80 mm |
19 mm |
(380 - 1100) nm | External up to 100W tungsten-halogen |
(0 - 57000) cd/m² @ CCT 2960K (0 - 39000) cd/m² @ CCT 2856K |
Fine adjustment, continually variable intensity control. | ||
ISS-8P-RVA-ROD | 80 mm | 360 - 830 nm | R 632nm, G 520nm, B 449nm, W |
Red 1.99 cd/m2 Green 2.01 cd/m2 Blue 1.98 cd/m2 White 2.00 cd/m2 |
Light field projected 200 mm in front of sphere. E.g. suitable for use with climatic chambers | |||
ISS-17-VA | 170 mm |
50 mm with resolution tube to suppress the lateral incident light (UMPA-2.0-xx) |
(380 - 800) nm | External 100W tungsten-halogen |
(3 - 7.500) cd/m² @ CCT 2856K (5 - 15.000) cd/m² @ CCT 3100K |
Monitor detector calibrated for color temperature and luminance | ||
ISS-17-VAM | 170 mm |
50 mm with resolution tube to suppress the lateral incident light (UMPA-2.0-xx) |
(380 - 800) nm | External 100W tungsten-halogen |
(3 - 7.500) cd/m² @ CCT 2856K (5 - 15.000) cd/m² @ CCT 3100K |
Monitor detector calibrated for color temperature and luminance | ||
ISS-30-VA | 300 mm |
100 mm |
(300 - 1100) nm @ CCT 2960K | External 100W tungsten-halogen |
(0 - 3500) cd/m² @ CCT 2960K |
Monitor detector calibrated for output port luminance | ||
ISS-30-VAM | 300 mm |
100 mm |
(300 - 1100) nm @ CCT 2960K | External 100W tungsten-halogen |
(0 - 3500) cd/m² @ CCT 2960K |
Monitor detector calibrated for output port luminance | ||
ISS-50-LU-FE | 500 mm | 3 x 100W tungsten-halogen each 2856K, 5000K or 6000K, filter wheel selected | Hemispheric illuminated field due to position of super wide-angle or fish-eye cameras in the sphere center. Three different color temperatures, switchable with filter wheels. | |||||
ISS-100-LT | 1000 mm | Configuration for veiling glare measurements of optics and camera systems. |