This product is no longer manufactured. Remaining stock may still be available. Please refer to the alternatives listed below under "Similar products" or contact us directly.

Alternative Products for this discontinued product:

BTS256-LED Tester
Compact BiTec Spectroradiometer LED Tester for the Measurement of Total Luminous Flux of Single VIS and NIR LEDs

RW-3704

Detector head for the measurement of irradiance in W/m²

  • spectral responsivity from 800 nm - 1000 nm (NIR)
  • cosine field-of-view
  • for the usage with optometers and amplifiers
  • calibration certificate
RW-3704

The spectral responsivity range of the model RW-3704 covers the NIR range from 800 nm to 1000 nm.

General Purpose Light Measurement Detector

The RW-37 series of radiometric detectors are primarily used for spectral broadband irradiance measurements within a defined spectral range of polychromatic radiation. Optical filters are used to shape the bare photodiode response to the desired spectral bandpass. The computer aided optical filter design produces the best possible broadband radiometric response within the spectral sector specified.

Cosine Field-of-View

A cosine F.O.V. characteristic of the detectors spatial responsivity is effected by the diffusor window of RW-37 detectors.

Designed for Wide Dynamic

The RW-37 detectors are designed for the highest possible irradiance sensitivity for low irradiance level applications. Hwever the wide range linearity of the photodiodes coupled with the Gigahertz-Optik optometers’s wide dynamic signal range amplifiers enable the RW-37 series detectors to be used in applications with high irradiances as well. The upper range is limited only by the detector maximum operating current and its specified operation temperature. 

Compact Housing

The RW-37 series irradiance detectors are built in a compact 37mm diameter black anodized aluminum housing. The shadow ring around the diffusor support the wide-angle cosine response. A side M6 tapped mounting hole allows the detector be fixed in place. The 37-type standard housing allows other SRT-M37 type accessories to be attached using the SRT-M45/37-B adapter for radiance or intensity measurements. 

Traceable Calibrations 

Calibration of irradiance in W/m² and/or W/cm² as well as the detector's relative spectral responsivity is performed at Gigahertz-Optik’s Calibration Laboratory. Besides the regular calibration with spectral broadband reference lamps alternative calibrations with monochromatic or custom type reference lamps can be supplied as an option. The calibration and its traceability are confirmed in the calibration certificate supplied with each detector.

Typical Spectral Responsivity

Typical Spectral Responsivity

Similar Products

RW-3704
Detector head for the measurement of irradiance in W/m²
RW-3704
Detector head for the measurement of irradiance in W/m²
RW-3704
Detector head for the measurement of irradiance in W/m²
RW-3704
Detector head for the measurement of irradiance in W/m²
RW-3704
Detector head for the measurement of irradiance in W/m²

Product Categories