Gigahertz-Optik Logo

Quick Contact

Gigahertz Optik GmbH (Headquarter)
Phone: +49 (0)8193-93700-0
info@gigahertz-optik.de

Gigahertz-Optik, Inc. (US office)
Phone: +1-978-462-1818
info-us@gigahertz-optik.com

Watchlist

You can add products to the watchlist and compare them with one another or send us an inquiry. There are watchlist symbols on product pages and product tables for this purpose.

This product is no longer manufactured. Remaining stock may still be available. Please refer to the alternatives listed below under "Similar products" or contact us directly.

Alternative Products for this discontinued product:

XD-45-ERYC

Detector for UV Hazard Measurements of Solaria (Sun Beds) and other Tanning Lamps in Accordance to UVSV

  • Features: Multi-cell detector for ERYTHEMA effective irradiance and UV-C evidence
  • 45 mm Diameter
  • For the usage with X1-4 optometer
  • Including calibration certificate
XD-45-ERYC

Mobile Erythemal Radiometer

The XD-45-ERYC-4 irradiance detector is specially designed for the measurement of the Erythemal effective UV radiation in tanning equipment. Gigahertz-Optik’s X14 optometer enables health and safety executives to do on-site measurements at the tanning salon conforming to published safety standards.

Measurement of the UV-C Limit Value

The relevant German UVSV (Verordnung zum Schutz vor schädlichen Wirkungen künstlicher ultravioletter Strahlung) specifies the limit values for Erythemal effective irradiance at 0.3 W/m² within the wavelength range from 250 nm to 400 nm. From 200 nm to 280 nm the irradiance should not exceed 0.003 W/m². The XD-45-ERYC-4 detector is set-up with a third UV-C sensor to measure any existing UV-C radiation at 254 nm with low uncertainty.

Cosine Corrected Field of View

The angular response of the XD-45-ERYC-4 detector is cosine corrected.

Traceable Calibration

Calibration of the detector responsivity is performed by the Gigahertz-Optik GmbH calibration laboratory for optical radiation measurements quantities. As with all light detectors supplied by Gigahertz-Optik calibration of absolute detector responsivity as well as detector individual measured relative spectral responsivity data is included.

Recommended Optometer

X14

XD-45-ERYC-4 - typical spectral responsivity

XD-45-ERYC-4 - typical spectral responsivity

Similar Products

XD-45-ERYC
Measure in the UV with this high-quality compact spectroradiometer
XD-45-ERYC
Photobiological risk group classification (spectral or integral measurement)

Product Categories